Pressure climbing to 3 bar in Birches Head, March 2025
Chris rang because his boiler pressure shot up to 3 bar whenever the heating came on. The safety valve was dumping water outside before the boiler went into an overheat lockout. It was an 8-year-old Glow-worm Flexicom combi in a terraced house.
The expansion vessel had no air charge, and water came out of its Schrader valve, which told me the diaphragm inside had split. The plate heat exchanger was partly blocked too. I replaced the expansion vessel and the weeping pressure relief valve, cleaned the heat exchanger and refilled the system to 1.2 bar.
It took around two hours. Through a full heating cycle afterwards, the pressure held between 1.2 and 1.5 bar.
In February 2025, Emma's Worcester Bosch combi in Hanley kept locking out because a blocked condensate trap had fouled the ignition electrodes; it was firing again in about an hour and a half. In April 2026 I collected keys from a Hanley letting agent for Richard, a landlord three hours away, did the safety check and a service in Shelton, and emailed him the certificate.
Nearby, I also cover Burslem and Bucknall, and every town I work in is listed on Areas We Cover.